Skip to main content

SMES Empirical standard deviations for stereo metric camera conditions

Columns

format

contents/explanation

1-4

A4

SMES

21-30
31-40
41-50

F10.0
F10.0
F10.0

sbx
sby
sbz

stability of base components

These standard deviations are uniformly valid for all stereo metric camera conditions. If zero is specified for a single value or for a group, the corresponding equations will not be established.