Zum Hauptinhalt springen

BINGO 7.6 - October 2024

Sprache
Diese Versionshinweise sind derzeit nur auf Englisch verfügbar.
Archived release

This page describes BINGO as it existed at the stated release date. For current behavior and requirements, use the current Manual, Reference, and Guides.

This release introduced several minor enhancements to BINGO and its tools.

BINGO

This release added the PCON statement and extended the GRUP statement.

To change the standard deviations of all photo measurements of control points, check points, or both, use the keywords CONT and CHCK in a GRUP statement instead of a range of point numbers or names.

Examples:

GRUP CONT 0.5
GRUP CHCK 10.0
GRUP CONT CHCK 0.7

This syntax can be combined with ranges of point numbers or point names. The total number of special groups remains limited to three.

The PCON statement allows photo projection centers in geoin.dat to be used directly as control points, without a GPS or IMU file or corrections for shift, drift, or the eccentricity vector ee'.

Example:

C <_____S_X____><_____S_Y____><____S_Z__>
COES 0.20 0.20 0.20
C
CONT N_3300100 -56837.880 58398.560 9.360
CONT N_3300500 -50380.240 64440.910 3.192
PCON A_4_007 -50184.446 59003.572 1704.796
PCON A_5_001 -54812.999 55708.921 1714.124
CONT N_3301000 -49961.810 62603.700 33.670
CONT N_3301300 -51046.820 57241.010 30.590

The same rules and values used for the coordinate standard deviations of CONT statements apply to PCON statements.

In bingo.lis, these control points are marked with P.

Example check print of input data:

Control points with standard deviations
Point X Y Z +- SX SY SZ Ctpt
-------------------------------------------------------------------------------------------
A_4_007 -50184.446 59003.572 1704.796 200. 200. 200. XYZ P <--
A_5_001 -54812.999 55708.921 1714.124 200. 200. 200. XYZ P <--
N_3300100 -56837.880 58398.560 9.360 200. 200. 200. XYZ
N_3300300 -53857.530 61136.070 5.020 200. 200. 200. XYZ
N_3300400 -51987.580 63675.110 3.270 200. 200. 200. XYZ

Example listing of residuals:

Residuals List limit = 0.0 * sigma
Type No.1 No.2 Residual Rii% W Nabla L
(1/1000) (1/1000)
---------------------------------------------------------------------------------------------
CONT X A_4_007 P -53.3 52 -0.4
CONT Y A_4_007 P 19.6 62 0.1
CONT Z A_4_007 P 10.8 28 0.1
CONT X A_5_001 P 70.9 53 0.5
CONT Y A_5_001 P -20.9 57 -0.1
CONT Z A_5_001 P -21.6 26 -0.2
CONT X N_3300100 -113.5 25 -1.1
CONT Y N_3300100 133.9 24 1.4
CONT Z N_3300100 -46.1 9 -0.8
CONT X N_3300300 125.5 67 0.8

In this release, REPLO and 3dView did not yet display points defined with PCON.